DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-402CLAN-BD (Control LAN Circuit Pack)
9
2012 ABORT Could not allocate the necessary system resources to run test.
2100 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
1
2
FAIL
FAIL
The buffer level is nearly exhausted.
The CLAN is congested, and no buffers are available.
1. Retry command at 1-minute intervals, up to 5 times.
2. If command continues to fail, examine the CLAN port measurements to
determine which ports are heavily utilized and the processor occupanc y
of the circuit pac k.
Low processor occupancy
when CLAN congested indicates circ uit pack
failure.
1. If the problem persists, reset the circuit pack (reset board UUCSS).
2. If congestion recurs, replace the circuit pac k.
High processor occupanc y
indicates the CLAN is congested due to traffic
load.
1. Busyout the circuit pack (busyout board UUCCS) to relieve congestion
selectively.
2. Consider replacing affected CLAN ports with new ports.
3 FAIL The CLAN circuit pac k is operating normally and is n ot congested.
PASS Hardware setting and attached cab le type match CLAN circuit pack
administration.
Table 9-169. TEST #600 Congestion Query Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page