Maintenance Object Repair Procedures
9-683DS1 CONV-BD
9
through every administered DS1 facil ity channel. Two different test patterns are
used, these are hexadecimal valu es 55 and AA.
On a Standard Reliability and Hig h Reliability System (no PNC duplication), th is
test can only be executed at the end-point whic h is closer to the SPE relative to
the neighbor DS1 CONV circuit pac k because of its impac ts on the system
control links, also the comp letion of the test will be delayed in this configuration to
wait for the recovery of the system control links. O n a Critical Reliability System
(PNC Duplication), test can b e executed at any DS1 CONV circuit p ack.
Figure 9-35. Far-end DS1 CONV Loopback Test (#788)
Table 9-264. TEST #788 Far-end DS1 Converter Board
Loopback Test
Error
Code Test
Result Description/ Recommendation
2000 ABORT Timed out while waiting for a response from the circuit pack.
2100 ABORT Could not allocate the nec essary system resources to run th is test.
2300 ABORT The downlink message necessary to run this test could not be sent to the
selected DS1C board.
2301 ABORT The timer could not be set before sending the downlink message necessary to
run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2316 ABORT Fiber link is not administered. Administer the DS1 CONV fiber link via the add
fiber-link command.
Continued on next page
Metallic or Fiber Connection
Metallic or Fiber Connection
Loops here
DS1CONVDS1CONV B
Network
A
Test starts here
or
SNI
EI or
SNI
EI