Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-754E-DIG-STA (Emulated Digital Line)
9
1000 ABORT System resources required to run this test are not available. The port is
busy with a valid call.
1. Use display port UUCSSpp to determine the station extension or
attendant number of the port.
2. Use status station or status attendant to determine the service
state of the port. If the port is in use, wait until it is idle before
retesting. Attendants are always in use (off-hook) if the handset is
plugged in and the port is not busied out.
3. Retry the command at 1-minute intervals a maximum of 5 times
1392 ABORT This is currently a TTI port, and the test cannot execute on it.
1. Verify that the port is a TTI port using either the display port
command (the display shows that the port is a TTI port) or the list
config command (the disp lay shows a t for the port).
2. If either list config or display port indicates that the port is
not
a TTI
port, escalate the problem. If both commands indic ate that the port
is a TTI port, the abort is correct, and no action is necessary.
FAIL Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The message to light all of the station lamps was sent su ccessfully to the
port.
1. Observe the station lamp s being lit when running the test. If al l lamps
do not light successfully, the other Digital Line test results may
indicate related problems that will not allow the lamps to light.
2. Investigate by using other Digital Line port tests and by examining
the station, wiring, and connections.
Table 9-291. TEST #16 DIG-LINE Station Lamp Updates Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page