Table 9-685. TEST #53 SAKI Sanity Test
Error
Code Test
Result Description/ Recommendation
None ABORT System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a maximum of 5
times.
1005 ABORT Wrong circuit pack c onfiguration to run this test. This error applies only to DS1
Interface circuit packs. It means the DS1 Interface circuit pac k is providing
timing for the system and, therefore, it cannot be reset without major system
disruptions.
1. If the circuit pack needs to be reset, then set synchronization to another
DS1 Interface circuit p ack or to the Tone-Clock circuit p ack and try again.
Refer to ‘‘SYNC (Synchronization)’’ Maintenance documentation.
1015 ABORT Port is not out -of-service.
1. Busyout the circuit pack.
2. Execute the reset board command again.
2100 ABORT System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a maximum of 5
times.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute the reset board command again.
2. If the problem persists, replace the circuit pack.
PASS The circuit pac k initializes correctly.
1. Run the Short Test Sequence.