June 1999
Maintenance Object Repair Procedures
9-132ASAI-EPT
9
System Technician-Demanded Tests:
Descriptions and Error Codes
When inspecting errors in the system, always inv estigate errors associated with
the circuit pack and port first. Clearing these error c odes first may also clear
errors generated against the end point. When all circuit p ack and por t errors have
been cleared, but e rrors still exist against the endp oint, investigate errors in the
table below. By clearing e rror codes associated with the Signaling Link Status
Test, for example, you may also clear errors generated from other tests in th e
testing sequence.
BRI Layer 3 Query Test (#629)
This test is not used by the ASAI-ADJ maintenance objec t. For information about
this test, see BRI-SET in the maintenance documentation.
79 Service or
option not
implemented
Requested service or option (or combination of selected options) is not
supported (implemented) in switch or the adjunct.
1. Consult switch and adjunct doc umentation to determine ASAI
service and options supported by both switch and adjunct.
Re-administration of the switch-administered capabilities (see
Customer Optional Feature Form) or those of the adjunct may be
necessary to correc t the problem.
81 Invalid CRV An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between the switch and the
adjunct. See the CallVisor protocol reference manual.
87 Internal switch
audit There is an inconsistency in switch data records.
1. There is no action needed, since the switch has corrected the d ata
inconsistency.
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
Signaling Link Status Test (#626) X X ND
Table 9-51. ASAI Cause Values — Continued
Code Explanation Recommendation
Continued on next page