DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-821EXP-INTF (Expansion Interface Circuit Pack)
9
1144 ABORT The packet bus in the PPN has a major alarm against it. This test needs to use
the alarmed PPN packet bus.
1. Enter display alarms and display errors and resolve any PKT-BUS
alarms.
2. Retry the command.
1394 ABORT The EI board is out of service and the test cannot be run. This condition is due
to a change in the EI board’s ability to communicate with the EI or Switch Node
Interface circuit pack on the other end of the fiber.
1. Run Test # 237 and c heck t he Error Lo g for EXP-IN TF Error Type 1 281. If
Error Type 1281 is present or if Test #237 does not pass, refer to repair
procedures for Test #237.
1395 ABORT This test cannot be run on an EI circuit pack if it is part of the B-side PNC and
Duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, enable PNC with the change
system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the set
PNC lock command.
3. Repeat this test.
1407 ABORT This test cannot b e run on an EI board that is on the active PNC b ecause it
cannot be busied out. This error code indicates that PNC duplication is
enabled.
1. Attempt to perform a PNC interchange via the reset pnc interchange
command.
2. If the PNC interchange is suc cessful, busy out the original Exp ansion
Interface circuit pack via the busyout board UUCSS (address of the
original EI board).
3. Retry the command.
2000 ABORT Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2060 ABORT The link on the pac ket bus being used to p erform the test has failed.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2. If the test continue to abort, enter display errors and resolve any PKTINT
errors.
2100 ABORT Could not allocate the necessary system resources to run this test.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 3 times.
Table 9-312. TEST #242 Expansion Interface Lightwave Transceiver Looparound — Continued
Error
Code Test
Result Description/ Recommendation