DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-331test ds1-loop
8
Parameters
location A [location] rep resents the physical posi tion of the
board to be tested . For Standard cabinets a loc ation is
entered as [UUcSS] where “UU” represents the
cabinet number, “ c” represents the c arrier, and “SS”
represents the slot position. A sing le digit cab inet
(1-3) are entered with or without a leading zero (0).
cpe-loopback-jack-test-begin1
1. The test will abort if the busyout command has not been set
For TN464F or TN767E or later suffix DS1 boards, this
causes a long-duration loop back test to be s etup
through the Customer Premises Equipment (CPE)
Loopback Jac k. The command allows you to specify a
loop-up code for the CPE loopback jack if it differs
from the default of 0x47F. Specify the number of bits in
the loop-up cod e as well as the actual bit-patte rn (in
hexadecimal).
far-csu-loopback-test-begin1For TN464F or TN767E or later suffix DS1 boards, this
causes a long-duration loop back test to be s etup
through the far-end Channel Service Unit (CSU).
one-way-span-test-begin1For TN464F or TN767E or later suffix DS1 boards, this
begins execution of a long -duration one-way span
test.
end-loopback/span-test For TN464F or TN767E or later suffix DS1 boards, this
parameter terminates long-du ration one-way span and
loopback testing.
inject-single-bit-error For TN464F or TN767E or later suffix DS1 boards, this
parameter causes a single bit error to be sent within
an active framed 3-in-24 test p attern used in
long-duration loopb ack and span testing .
ds1/csu-loopback-tests For TN464F or TN767E or later suffix DS1 boards, this
parameter executes the following loopback tests: DS1
Board LoopBack, CSU Module Equipment LoopBack,
and CSU Module Repeater LoopBack. These tests are
performed sequentially fo r a short duration each, and
individual PASS/FAIL/ABORT test results are reported
following each test.