DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-718DUP-CHL (Duplication Interface)
9
1325 ABORT Memory shadowing is inhibited from the standby SPE.
1. Shadowing may not be turned on yet, so wait 5 minutes and run the test
again.
2. Rerun the test; if the same 1325 abort occurs again, use the display
alarms command and select Category spe. If any mainte nance objects
other than DUPINT or DUP-CHL have MAJOR alarms, fix these problems.
Problems causing MAJOR alarms for MEM-BD, PKT-INT, SYSAM,
H-ADAPTR, and SW-CTL should be repaired first.
3. Rerun the test; if the same 1325 abort occurs again, look for other DUPINT
or DUP-CHL test failures by using th e busyout spe-standby if not already
busied out and the test duplication-interface long clear commands. Fix
these problems acc ording to the service d ocumentation for these packs .
4. If this 1325 abort continues to occur, the standby SPE may not have
initialized proper ly. Use the lock-and-power-down p rocedure described in
Chapter 5 to power down and power up the standby SPE, but don’t
replace any circ uit packs.
1411 ABORT This test did not run because the standby Duplication In t erface circuit pac k
cannot be detected as being plugged in by the software.
1. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure desc ribed in Chapter 5
to power down and power up the standby SPE, but don’t replace any
circuit packs.
2000 ABORT This test did not run because communication with the standby timed out while
waiting for a reply to a maintenance message.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure desc ribed in Chapter 5
to power down and power up the standby SPE, but do not replace any
circuit packs.
2334 ABORT The hardware mailbox in the standb y Duplication Interface c ircuit pack is not
ready to receive messages.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure desc ribed in Chapter 5
to power down and power up the standby SPE, but don’t replace any
circuit packs.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 9-278. TEST #875 Remote SPE Error Interrupt Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page