Maintenance Object Repair Procedures

9-716DUP-CHL (Duplication Interface)

9
Remote SPE Error Interrupt Test (#875)

This test is used to check for the c orrect operation of the Remote SPE Error

interrupt

2334 FAIL The hardware mailbox in the standby Duplication Interface circuit pac k is not
ready to receive messages.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this failure continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure desc ribed in Chapter 5
to power down and power up the standby SPE, but do not replace any
circuit packs.
3. Replace Duplication Interface comp onents starting with the standby
Dupl icati on Int erfac e ci rcuit pac k. Use SPE Dupli cati on Chan nel
Component Replacement procedures at the end of this section.
PASS The stan dby softwa re ret urned the te st mess age s ent fro m the a ctiv e SPE to the
standby SPE via the Duplication Interface circuit pack mailbox.
Table 9-277. TEST #874 Duplication Channel Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page