DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-924HYB-LINE (Hybrid Line)
9
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
2. Retry the command at 1-minute intervals a maximum of 5 times.
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a t for the port).
2. If either list config or display port indicate that the port is
not
a TTI port,
escalate the problem. If both commands indicate that the p ort is a TTI
port, the abort is correct, and no action is necessary.
2000 ABORT Response to the test request was not received within the allowable time
period.
Table 9-355. TEST #61 Hybrid Line Audits Test — Continued
Error
Code Test
Result Description/ Recommendation