DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-925HYB-LINE (Hybrid Line)

9
Hybrid Line Ringer Update Test (#62)

In this update, a ‘‘ringer on’’ or a ‘‘ring er off’’ message is sent to the firmware to

start and stop the ring er on the set.

FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS Hybrid Line Audits Test passed.
1. Although this test will never actually return a FAIL result except for the
Internal system error described above, it is possible that it will enter
Error Types 257 or 513 into the Error Log. To determine if there are any
problems that don’t show up in the test result, look for these Error Types in
the Error Log.
2. If these errors appear in the Error Log, or if user complaints still exist,
investigate by using other circuit pack tests, and b y examining the station,
wiring, and connections.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correc tly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Table 9-355. TEST #61 Hybrid Line Audits Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page