DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-801EXP-INTF (Expansion Interface Circuit Pack)
9
Notes:
a. This error indicates that the Expansion Interfac e circuit pac k has been
busied out via the busyout board UCSS co mmand. To resolve this error,
release the Expansion Interface circ uit pack via the release board UCSS
command.
b. Expansion Interface circ uit pack has be en administered on the Circuit
Pack form, but has not been p hysically inserted into the system. Insert the
circuit pack.
c. A wrong circuit p ack is located in the slot where this circuit pac k is
logically administered . To resolve this problem, either remove the wrong
circuit pack and insert the logically ad ministered circuit p ack OR use the
change circuit-pack command to readminister th is slot to match the
circuit pack that is p hysically inserted in this slot. If a fiber is administered
to this circuit pac k the fiber must be removed via ad ministration before the
circuit pack c an be removed from admi nistration.
3074(n) 2 Expansion Interface Packet
Interface Test(#589) MAJ OFF test board UUCSS r 3
3075(n) 1 Expansion Interface Packet
Interface Test(#589) MAJ OFF test board UUCSS r 3
3076 Expansion Interface Packet
Interface Test(#589) MAJ OFF test board UUCSS r 3
3330(o) Any None WRN ON
3585(p) 0 None WRN OFF
3841(q) Any None MIN OFF (s)
3842(r) Any None MIN OFF (s)
10001(t) 0 None
1. Aux Data 32767 for any error log entry indicates that an alarmed EI was busied out and then
released. When this occurs, existing service affecting alarms must be preserved. As is typical, when
the EI is released all alarms are resolved. Therefore the alarm and error logs must be repopulated
with the alarms present at time of busy out. This error code is an indication that existing aux data and
error log time stamps are no longer valid because they were lost when the alarms were resolved
upon release of the circuit pack.
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
Table 9-306. EXP-INTF Error Log Entries — Continued
Error
Type Aux
Data1Associated Test Alarm
Level On/Off
Board Test to Clear Value