Insertion Loss for Port-to-Port; Analog or Digital
Table 1-14 lists the insertion loss in the system for di fferent connection types for
the United States. Table 1-15 shows the overload and cross-talk characte ristics.
Intermodulation Distortion
Table 1-16 lists the intermodulation d istortion in the system for analog-to-analog
and analog-to-dig ital, up to 9.6 kbps d ata
Table 1-14. Insertion Loss for the United States
Typical Connections Nominal Loss
(dB) at 1 kHz
On-premises to on-premises station 6
On-premises to off-premises station 3
Off-premises to off-premises station 0
On-premises station to 4-wire trunk 3
Off-premises station to 4-wire trunk 2
Station-to-trunk 0
Trunk-to-trunk 0
Table 1-15. Overload and Crosstalk
Overload level +3 dBm0
Crosstalk loss >70 dB
Table 1-16. Intermodulation Distortion
Four-Tone Method Distortion
Second-order tone products >46 dB
Third-order tone products >56 dB