DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-426CO-DS1 (DS1 CO Trunk)
9
PASS The trunk can be seized for an outgoing call.
0NO
BOARD The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, an insane boar d is inserted, or the boar d is
hyperactive.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Hyperactivity causes some special problems with the sequence sug gested
above. If the ports are translated after issuing the list config command but
the ’Vintage’ field reports that there is no board (when there really is a
board), then the busyout board and the release busy board commands
will not work (even though the reset board command will work). The
software will put the hyperactive board back in service after the
hyperactivity clears.
Table 9-178. TEST #314 DS1 CO Dial Tone Seizure Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page