DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-188ATM-EI (Expansion Interface Circuit Pack)
9
1033 ABORT The test cannot run because either the ATM-EI board is not administered, or
there were no other PNs administered that had its ATM-EI board in-service.
1. Ensure that the board is administered as ATM PNC Expansion Interface
circuit pack.
If the board is administered as ATM-EI circuit pack, then there has been
some change in the ability of the ATM-EI circuit pack in the other PNs to
communicate with the ATM-EI on the other end of its connection.
2. Using status port
x
(the port-network number in which the board is
administered), see if both ACL and EAL are up to this board. If they are
not, see the service procedure for SYS-LINK.
3. Check the Error Log for Error Type 1281 with Aux Data 27 (board cannot
talk to the ATM switch). See Table 9-77 for repair proced ures.
If present, check both the ATM switch and the DEFINITY administrations
for consistent ATM addresses. Reset the b oard and see if the problem
resolves.
4. Repeat Test #241. If it continues to abort with this abort code, replace
the boa rd.
1394 ABORT 1. See Table 9-77 (Error Type 1281) with Aux Data 27 (board cannot talk to
the ATM switch), and if present, check both the ATM switch and the
DEFINITY administrations for consistent ATM addresses.
2. Reset the board and see if the problem resolves.
3. Repeat the test.
1395 ABORT This test cannot run on an ATM-EI circuit pack if it is part of the B-side PNC
and Duplicated PNC is not enabled.
1. If this test needs to run on this ATM-EI circuit pack, enable PNC with the
change system-parameters duplication command.
2. Prevent the system from doing a PNC interc hange by executing the set
PNC lock command.
3. Repeat this test.
1413 ABORT This test requires the use of a Tone/Clock circuit pack in each of the port
networks (PN) used in this test. This abort code indicates that a Tone/Clock
circuit pac k is not present in one of the PNs.
1. Make sure that there is a Tone/Clock circuit pack located in the PN in
which the ATM PNC Expansion Interface circuit pack und er test is
located.
2. In ATM PNC configurations, make sure that ther e is at leas t one othe r P N
besides the PN where the ATM-EI circuit pack under test resides that
contains a Tone/Clock circuit pack.
Table 9-80. Expansion Interface 2-way Transmission Test (#241) — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page