DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-424CO-DS1 (DS1 CO Trunk)
9
Table 9-178. TEST #314 DS1 CO Dial Tone Seizure Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT The test was aborted because system resources required to run this test
were not available. The port may be busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
2. If the port status is active but the port is not in use (no calls), chec k the
error log for error type 1025. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1004 ABORT The test was aborted because the port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1005 ABORT Test failed due to incompatible configuration administered in trunk group
form.
1. Look at the trunk group administration form and see whether the trunk
is incoming only, port 24 on a DS1 Interface with common c o ntrol
channel signaling, or an automatic CO type such as FX. Under any of
these conditions this is a normal abort.
1018 ABORT Test is disabled via translation. You may want to determine why the test has
been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk Group’ for m is set
to ’n’. To enable the test, issue the cha nge trunk-group x command (x
equals the number of the trunk group to be tested). Then, change the
entry in the ’Maintenance Test’ field on the form to ’y’.
2. Repeat the test.
1040 ABORT The test was aborted because this port may be an access endpoint.
1. Verify that this port is an access endpoint by issuing the display port
command.
2. If the port has been administered as an acc ess endpoint, then this is a
normal abort.
Continued on next page