DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1152PDATA-PT (Packet Data Line Port)

9
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs if the LAPD Connectivity test fails. If this test fails repeatedly, a MINOR alarm is raised. This alarm indic ates the failure to establish a LAPD link with the port and to send and receive test data over that port. See the repair proced ure for LAPD Connectivity Test (#558).b. This error type indicates that the c ircuit pack has b een removed or has been insane for more than 11 minutes. To clear the error, reinsert or replace the circuit pack.
Table 9-457. PDATA Port Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Levell1
1. Major or Minor alarms on this MO may have been downgraded to Warning alarms based on the values
used in the set options command.
On/Off
Board Test to Clear Value
02
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
Any Any Any test port UUCSSpp sh r 1
1(a) LAPD Connectivity
Test (#558) MINOR ON test port UUCSSpp r 3
18 Busy Port WARNING OFF release port UUCSSpp
130(b) None WARNING ON test port UUCSSpp sh
257(c)
513(c)
779(c)
1025(d) Translation RAM
Update MINOR ON see footnote (c)
1281(e)
1793(f) Port Local
Loop-Around Test
(#602)
MINOR ON test port UUCSSpp
2049(g) System Port
Connectivity Test
(#603)
MINOR OFF test p ort UUCSSpp
3842*
3843*
3844*
37914 test port UUCSSpp sh l