DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1848UDS1-BD (UDS1 Interface Circuit Pack)
9
Table 9-687. TEST #138 Loss of Signal Alarm Inquiry Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2000 ABORT Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and one or more of
the following symptoms may be exhibited.
1. The UDS1-BD tests (such as test 138 and test 139) are aborting with error
code 2000.
2. The tests run on the ports of this circuit pack are returning a no board
result.
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the c ircuit pack and the ports are
properly installed.
When hyperactivity occurs, the circuit pack is isolated from the system, and all
of the trunks for this circuit pack are placed into the out of service state. The
system will try to restore the circuit pack within 15 minutes. When no faults are
detected for 15 minutes, the UDS1 interface circuit pack is restored to normal
operation. All of the trunks for the UDS1 interface circuit pack are then returned
to the in service state. Hyperactivity is often caused by the associated facility. In
such a case, faults (such as slips, misframes, or blue alarms) would be entered
in the error log. In addition, many hardware errors would be logged against the
associated trunk circuits. If the facility is OK and the error occurs again after 15
minutes, replace the circuit pack.
2100 ABORT Could not allocate the nec essary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page