DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-815EXP-INTF (Expansion Interface Circuit Pack)
9
1395 ABORT This test cannot be run on an EI circuit pack if it is part of the B-side PNC and
Duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, enable PNC with the change
system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the set
PNC lock command.
3. Repeat this test.
1413 ABORT This test requires the use of a Tone/Clock circuit pack in each of the port
networks used in this test. This abort code indicates that there are none of these
circuit packs located in one of the PNs.
1. Make sure that there is a Tone/Clock circ uit pack located in the PN in which
the Expansion Interface circuit pack under test is located.
2. In Direct Connect configurations, make sure that there is a Tone/Clock
circuit pack located in the PN where the neighbor Expansion Interface
circuit pack is located.
3. In Center Stage Switch configurations, make sure that there is at least one
other PN, besides the PN where the EI circuit pack under test resides, that
contains a Tone/Clock circuit pack.
1414 ABORT This test requires the use of an active Tone/Clock circuit pack in each of the port
networks used in this test that does not have a MAJOR or MINOR alarm logged
against it. This abort code indicates that the active Tone/Clock circuit pac k in
one of the port networks being used for the test has a MAJOR or MINOR alarm
logged against it.
1. Enter display alarms and resolve all TONE-BD and TONE-PT alarms.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required to run this test are not available.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 3 times.
FAIL The test tone was not detected correctly in either direction.
1. Run the test for the Active Tone-Clocks on the Port Networks for which the
Expansion Interface circuit pack under test provides a link. This will
determine if the dial tone is being supplied.
2. Perform the ‘‘Fiber Fault Isolation Procedure’’ in Chapter 5, ‘‘Alarms, Errors,
and Troubleshooting’’.
Table 9-311. TEST #241 Expansion Interface 2-way Transmission Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page