DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-261ATM-TRK (Circuit Emulation Service Circuit Pack)
9
5. Check capacity and peak band width consumption for the ATM
span.
h. Error Type 771: the ATM switch is sending cells with unknown Virtual
Path-Identifier (VPI) and Virtual Channel-Identifier (VCI) addresses.
1. Make sure that the ATM-TRK circuit-pack address is administered
identically on the ATM switch and the DEFINITY ECS.
i. Error Type 1281: Board major signals error (loss of high-level si gnal). The
far-end has detected a major problem in transmissions ori ginating from
the ATM-TRK circuit pack. The possible Aux Data values for this software
counter are listed in Table 9-118.
If Then
The ATM-TRK circuit pack
fails the loopback test. The problem is in the ATM-TRK circuit
pack. Replace t he circuit pac k.
The far-end circuit p ack or
ATM switch fails the
loopback test.
The problem is in the far-end circuit pac k
or ATM switch. Consult the circuit-pack
or ATM switch documentation for advice.
The equipment at each
end of the ATM span
passes the loopback test
The problem is somewhere in the ATM
span. Lack of bandwidth may be forcing
an intermediate ATM switch to drop cells.
If Then
The capacity of the
span is inadequate or
bandwidth consumption
is too high.
Reduce traffic on the G3V4 switch to
ensure that it is using no more that its
subscribed bandwidth.
Table 9-118. Error type 1281 Aux Data and repair procedures
Aux
Data Alarm
Description Repair procedure
15 SYSCLOCK failed The boa rd is n ot loc ked t o the TDM bac kplan e clo ck sig nal. This is
probably due to a Tone Clock problem.
1. Check for TDM-BUS or TONE-BD errors in the Error Log.
2. If no other problems are present, reset the circuit pack (reset
board UUCSS)
Continued on next page