DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1727TDM-CLK (TDM Bus Clock)
9
Notes:
a. Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation
for descriptions of these tests.
b. Refer to TONE-BD (Tone-Clock Circuit Pack) documentation for a
description of this test.
c. Refer to TONE-PT (Tone Generator) documentation for descriptions of
these tests.
d. This test only runs on the Standby Tone-Clock circuit p ack in a Port
Network with more than one Tone-Clock circuit pack (Hig h or Critical
Reliability Option). The circuit p ack must be a TN780 cod e with firmware
revision 2 or above, or be a TN2182.
e. Test #149 is not run on the TN2182.
TDM Bus Clock Circuit Status Inquiry Test (#148)
The TDM Bus Clock circuitry is ch ecked for sanity. Any problems that are fo und
are reported via error cod es
TDM Bus Clock Parameter Update Test
(#151) XX ND
Board Type Check Test (#574) X X ND
Standby Reference Health Check Test
(#651) (d) XND
1. D = Destructive; ND = Nondestruc tive
Table 9-646. TEST #148 TDM Bus Clock Circuit Status
Inquiry Test
Error
Code Test
Result Description/ Recommendation
None
1001 ABORT The system could not allocate the necessary resources for the test.
1. Wait 1-minute, and retry the test.
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT System resourc es required to run thi s test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Order of Investigation Short Test
Sequence Long Test
Sequence Reset Board
Sequence D/ND1