9-439CO-TRK (Analog CO Trunk)

9
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the se lected time slot and never crosses over to time slots rese rved for other connections. If the NPE is not working correctly, one way and noisy connec tions may be observed. This test is usually only part o f a port’s long test seq uence and takes approximately 20 to 30 second s to complete.
Table 9-183. TEST #6 NPE Crosstalk Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use th e status trunk command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
2. If the port status is active but the port is not in use (no calls), chec k the
error log for error type 1025 (see the error log table for a description of
this error and required actions). The port may be locked up. Check the
CO wiring, check for excessive loop c urrent, and check t he trunk
translations. (If the trunk is translated incorrectly, this test will abort.)
3. If the port status is idle, busyout and release the trunk, and retry the
command at 1-minute intervals for a maximum of 5 times.
4. If the test still aborts, replace the circuit pack.
1001 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic c onditions or it may have ti me slots out-of-service d ue to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, retry
the command at 1-minute intervals for a maximum of 5 times..
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals for a
maximum of 5 times.