DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-333test ds1-loop
8
If the [inject-single-b it-error] parameter is selec ted, but no CPE Loopback Jac k,
far-end CSU, or one-way span test is active on th e DS1 circuit pack, then the
following message will be displayed:
Parameter valid only if a loopback/span test is active on the DS1
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
For the following output example, assume that the board in cabinet 1, c arrier c,
slot 7 is a TN767E DS1 board. The command that was entered was test ds1-loop
1c07.
Feature Interactions
Loopback or sp an tests will not be allowed on DS1 board s unless the board has
been busied out.
Port The port address (cab inet-carrier-slot-circ uit) of the maintenance
object that is being tested.
Maintenance
Name The type of maintenance objec t that is being tested.
Alt. Name The alternate means of identifying the maintenanc e object.
Test No The actual test that is being exec uted.
Result The result of the individual test - PASS, ABORT, FAIL, NO BOARD,
DISABL ED, EXTRA BD .
Error Code A system-generated numb er that tells why the release failed or
aborted. A detailed list of the codes acc ording to “Test No.” is
provided for eac h MO.
test ds1-loop 01C07 ds1/csu-loopback-tests
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C07 DS1-BD 1209 PASS
01C07 DS1-BD 1210 PASS
01C07 DS1-BD 1211 PASS
Command Successfully Completed