DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1879UDS1-BD (UDS1 Interface Circuit Pack)
9
Translation Update Test (#146)
The Translation Update Test sends the circuit-pack-level information sp ecified by
System Administration to the UDS1 Interface circu it pack. Translation includes
the following data administ ered for a UDS1 Interface circuit p ack (see output of
display ds1 UUCSS command): DS1 Link Length b etween two DS1 endpoints,
Synchronization Source Control, All Zero Suppression, Framing Mode, Sig naling
Mode, Time Slot Number of 697-Hz Tone, Time Slot Number of 700-Hz Tone, etc.
In G3V3, if a TN464F or later UDS1 circuit pack is comb ined with an Lucent
120A1 CSU Module to form and Integrated CSU Module, this test will also send
the administration for this Integrated CSU to the circuit pack to assure the
board’s translations are correc t. The administration of the CSU Module is done
using the DS1 circuit pac k administration form. Translation for the CSU Module
includes the following d ata: Transmit LBO, Receive ALBO, Supply CPE
Loopback Jack Power, etc.
Table 9-695. TEST #146 Translation Update Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute interval s a maximum of 5 times.
FAIL Internal system software error.
1. Enter the display ds1 UUCSS command to verify the UDS1 Interface
circuit pack translation.
PASS Translation data has been downloaded to the UDS1 Interface circuit pack
successfully.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane b oard is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to admini ster the UDS1 interface if it is not alread y
administered.
2. If the board was already administered correctly, check the error log to
determine whether the b oard is hyperactiv e. If this is the case, the board is
shut down. Reseating the b oard will re-initialize the board .
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Continued on next page