DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-137ASAI-PT
9
c. The port received an invalid frame over the D-channel. When the Cyclical
Redundancy Check (CRC) errors exc eed 5 within 15 minutes, the port is
taken out of service for 5 second s. If 5 more CRC errors are received
within 15 minutes of the first set of 5 errors, the port is taken out of service
for one minute. If 5 more CRC errors are received within 15 minutes of the
last 5, the port is taken out of servic e for 15 minutes.
This error is most likely due to a problem with the wiring to the set or
adjunct, interference on the wiring due to a noise source, or no termination
(an open circuit). It usually d oes not indicate a p roblem with the circuit
pack.
Check the wiring to the end points or the adjunct.
If the problem persists, rep lace the endpoints or ad juncts.
d. This error occurs when a Layer 1 Transmission error is detected for th e
port. Run the Long Test Sequence and note the results of the Layer 1
Transmission Error Counter Test (#624).
e. This error occurs when the circuit pac k detects an overflow of it s receive
buffers. Run the Long Test Sequence and note the results of the Receive
FIFO Overflow Counter Test (#625).
f. This error occurs when the BRI Port Local LAN Looparound Test (#618)
fails. Run the Long Test Sequence and note the results of Test (#618).
g. The Terminal Endpoint Identifier (TEI) administered for the ASAI endpoint
most likely does not match the TEI administered in t he ASAI adjunct.
Check the switch administration of the TEI against that of the adjunc t, and
make sure that both are using the same TEI.
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the following tabl es when
inspecting errors in the system. For examp le, by clearing error c odes associated
with the NPE Crosstalk Test, you may also clear errors generated from other tests
in the testing sequenc e.
Table 9-54. System Technician-Demanded Tests: ASAI-PT
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
ASAI Port Local LAN Looparound Test (#618) X D
Level 1 Status Inquiry Test (#621) X X ND
CRC Error Counter Test (#623) X ND
Continued on next page