DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-987MAINT (EPN Maintenance Circuit Pack)
9
2033 ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum of five times.
2046 ABORT The EPN Maintenance circuit pack reported an invalid cabinet type. Not
knowing the cabinet type of the EPN will prevent all EPN environment
maintenance from running.
1. Retry the command.
2. If the test continues to abort with 2046, then either the EPN Maintenance
circuit pack is defective, or the EPN cabinet wiring is defec tive. First,
replace the EPN Maintenance circuit pack.
3. If the test continues to abort with 2046, then the EPN cabinet wiring is
defective in the A carrier and the EPN Maintenance circuit pack cannot
read the backplane pins to determine the cab inet type.
10601 ABORT Test disabled via software patch.
Table 9-378. TEST #106 Sanity Handshake Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page