DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-48change circuit packs
8
Parameters
Output
An input form is disp layed containing the followi ng fields:
The following display shows a typ ical result when change circuit-packs 1 is
entered on a system with simplex SPE and a Center Stage Switch (cab inet 1 is
always 5-carrier).
UU The number of the cabinet containing the circuit pac ks to be modified. Default is 1.
Cabinet The administered number of the c abinet (1-22).
Cabinet
Layout Type of cabinet.
Carrier Each page of this form reports the in formation for 1 carrier. This field
indicates the letter des ignation of the carrier disp layed on the current
page.
Carrier
Type The function of the carrier: (port, p rocessor, switch-nod e,
dup-switch-nod e, or not-used).
Slot The carrier slot numbers (00 - 21).
Code The TN or UN part number of the circuit p ack. This number identifies
the circuit pac k type to system software.
Sfx The letter suffix of the circuit pac k, if applicab le.
Name The name of the circuit pack . This field aids in entering the c ircuit pack
codes.
change circuit-packs 1 Page 1 of 5
CIRCUIT PACKS
Cabinet: 1 Carrier: A
Cabinet Layout: five-carrier Carrier Type: processor
*** PROCESSOR BOARDS NOT ADMINISTERABLE IN THIS SCREEN ***