DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-636DS1-FAC (DS1 Facility)
9
DS1-FAC (DS1 Facility)
The DS1-FAC is a part of the DS1 Converter (DS1 CONV) Complex. The DS1
CONV Complex consists of two TN574 DS1 CONV circuit packs or two TN1654
DS1 CONV circuit packs connec ted by one to four DS1 facilities. The
maintenance object name for the DS1 CONV circuit pack is DS1C-BD, and the
maintenance object name for the connected DS1 facilities is DS1-FAC.
The TN1654 DS1 Converter Circuit pack is a redesig n of the TN574 DS1
Converter board. The TN1654 provides func tionality equivalent to the TN574 but
also adds a 32-Channel E1 interface for international support as well as
circuit-switched wid eband connec tions (NxDS0).
The TN1654 DS1 CONV circuit pack is not compatib le with the TN574 DS1
CONV board or the Y-cable used to inter face to the TN574 DS1 CONV. A
TN573B or later suffix SNI board must also be used when c onnecting to the
TN1654 DS1 CONV board. See section DS1C-BD for information on both DS1
CONV circuit packs.
The DS1 CONV Complex is a part of the Port Network Connectivity (PNC). The
DS1 CONV Complex is used to extend the range of the 32 Mbps fiber links that
connect EPNs to either the PPN or the Center Stage Switch, allowing EPNs to be
located at remote sites.
The DS1 CONV circuit pack contains on-board fi rmware that detects DS1 facility
alarms and errors, communicate s status to maintenance software, and runs tests
in the background or on demand from maintenanc e software. The overall
maintenance software strategy inc ludes demand tests, rec overy strategies, error
logging and alarm logging, and periodic audits.
Every error condition reported by the firmware is associated with the background
tests that the firmware runs autonomously. Demand tests that are executed by
the maintenance software do not have any func tionality that would effect any
additional error manipulation b y the firmware. However, the Failure Audit test
MO Name (in
Alarm Log) Alarm Level Initial Command to Run1
1. UU is the universal cabinet number (1 for PPN, 2-44 for EP Ns). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21). f is the
DS1 facility (a, b, c, or d). See Chapter 7, or the DS1C-BD section, for identification of DS1
facility LEDs.
Full Name of MO
DS1-FAC MAJOR test board UUCSS sh r 1 DS1 Facility
DS1-FAC MINOR test board UUCSS sh r 1 DS1 Facility
DS1-FAC WARNING test board UUCSS sh r 1 DS1 Facility