DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-468DC-POWER (Single Carrier Cabinet Environment)
9
Hardware Error Log Entries and Test to Clear
Valu es
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the following table when
inspecting errors in the sys tem. By clearing error codes assoc iated with the
Single Carrier Cabinet Power Query Test
, for example, you may also clear errors
generated from other tests in the testing sequence. Test description(s) and
recommended maintenanc e procedures follow for all errors that can oc cur
during system technic ian-demanded testing.
Notes:
a. Refer to EMG-XFER (E mergency Transfer) Maintenance documentation for
a description of this test.
b. Refer to EXT-DEV (E xternal Alarm Lead) Maintenance documentation for a
description of this test.
c. Refer to RING-GEN (Analog Ring Generator) Maintenance docu mentation
for a description of this test.
Single Carrier Cabinet Power Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value1
1. UU is the universal cabinet number indicated in the PORT field of the Alarm Log.
02
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test environment UU
513 0 or 1 Single Carrier Cabinet
Power Query (#79) MAJOR ON test environment UU r 2
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
Single Carrier Cabinet Power Query Test (#79) X X ND
Emergency Transfer Query Test (#124) (a) X X ND
External Alarm Lead Query Test (#120) (b) X X ND
Analog Ring Generator Initializ ation Test (#117) (c) X X ND
Analog Ring Generator Query Test (#118) (c) X X ND