DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-326BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)]
9
Electronic Power Feed Inquiry (#622)
This test queries the BRI-LINE circuit pack for the status of the Electronic Power
Feed (EPF) supplied to a BRI endpoint or an ASAI or Lucent adjunc t. If the EPF is
on and no overcurrent cond ition exists, this test passes. All other states are not
normal and indicate a problem with the endp oint or adjunct, the wiring to the
endpoint or adjunc t, or the BRI-LINE circuit pack. This test is not run on the
TN2208 circuit pack or the TN2198 and will always return a pass for the TN2198.
The TN2208 has no power feeds.
4 FAIL For the TN2198 only:
Received a status of Level 1 Pending Activation, the NT1 has a loss of power
indicating a problem with the NT1.
1. For the NT1 follow the manufacturers recommended repair procedures.
2. Execute the test port PCSSpp command, and review the results of the
Level 1 Status Inquiry test to verify the repair. If the test is still failing
proceed to Step 3.
3. Escalate the problem to the next tier.
PASS This test indicates that Level 1 is activated, or that software has taken the
port out of service.
Table 9-144. TEST #622 Electronic Power Feed Inquiry
Error
Code Test
Result Description/ Recommendation
1005 ABORT This test is not valid for this port type. Ports on the TN2208 can not run this
test because this b oard does not have an ele ctronic power fe ed.
2000 ABORT Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of five times, reset the circuit
pack via the busyout board PCSS and reset board PCSS commands.
2. If the test aborts again, replace the circuit p ack.
Continued on next page
Table 9-143. TEST #621 Level 1 Status Inquiry — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page