DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1326PPP-PT (Control LAN Packet/Port)

9
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 001: SCOTCH Synchronous Looparound Test (#1275) failed.1. Test the port (test port UUCSSpp long).2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair procedures.b. Error Type 257: CLAN port detected overrun or underrun conditio n that may indicate a hardware p roblem. 1. Test for hardware problem (test port UUCSSpp long).
Table 9-516. CLAN Port Error Log Entries
Error Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port UUCSSpp s
1 (a) 0 SCOTCH Sync
Looparound
Test (#1275)
MINOR ON test p ort UUCSSpp l r 3
257 (b) 0 Under-run/Over-run
Error WARNING OFF
513 (c) 0 PPP Link Failure MINOR OFF
769 (d) 0 Invalid Frame Error WARNING OFF
1281 (e) 0 Far-end disconnec t
1537, 1538
(f) See
note Session Status Test
(#1286) MINOR OFF
1793-1920
(g) See
note Socket Failure
2305-2560
(h) See
note Session Down error
Session #s 1-256
2561-2816
(h) See
note Session Down error
Session #s 257-512
3329 (i) 35768 TCP/IP Ping Test
(#1281) WARNING OFF
3585 (j) 0-1 TDM Looparound
Test (#1285) MAJOR ON test port UUCSSpp l r 3