DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-810EXP-INTF (Expansion Interface Circuit Pack)
9
Table 9-310. TEST #240 Expansion Interface Local Looparound
Error
Code Test
Result Description/ Recommendation
1 ABORT Could not allocate time slot on TDM Bus A. Loopback passed on TDM Bus B.
2 ABORT Could not allocate time slot on TDM Bus B. Loopback passed on TDM Bus A.
1. If there is no reason to doubt that the EI circuit pack can transfer data to or
from a TDM Bus, then since the test passed on one bus, assume that the
test passes on the other bus.
2. If this test continues to abort with the same error, rerun test at 1-minute
intervals a maximum of 3 times.
3. If the test still does not pass on the other TDM Bus, follow the procedure
for ABORT Error Code 3.
3 ABORT The system could not allocate time slots for the test on either TDM Bus. The
system may be under heavy traffic conditions or it may have time slots
out-of-service due to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, retry
the command at 1-minute intervals a maximum of 3 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors
may be out of service.
1. Enter display errors and follow associated repair procedures for TTR-LEV
errors in the error log. Even if there are not TTR-LEV errors, there may not
be a tone detector available on the network that contains the circuit pack
being tested. Verify that there is at least one tone detector on the network.
If not, this test always aborts for this EI circuit pack. This does not harm the
system.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 3 times.
1031 ABORT A query of the EI circuit p ack aborted. The purpose of this query was to see if
the EI circuit pack could detec t the framing signal.
1. If Test #238 aborted, follow the p rocedure associated with this abort cod e.
2. If Test #238 did not abort, rerun Test #240 at 1-mi nute interv als a maxim um
of 3 times.
1032 ABORT The EI cannot detect the framing signal and cannot run the test.
1. Refer to the errors for Test #238 to determine why the EI circuit pack is out
of frame.
Continued on next page