Maintenance Object Repair Procedures
9-1859UDS1-BD (UDS1 Interface Circuit Pack)
9
FAIL The UDS1 interface circuit pack detected a red alarm. An out of frame
condition occurred on the UDS1 interface circuit pac k. The UDS1 interface
circuit pack will transmit a yellow alarm to the remote UDS1 endpoint until the
red alarm i s retired.
If the UDS1 connects to a T1 network facility or to another switch, do the
following.
1. Verify that both endpoints of the DS1 link are administered using the same
signaling mode, framing mode, and line coding.
2. Contact T1 Network Service or a technician at the far-end switch to
diagnose the remote DS1 endpoint.
3. Check the physical connectivity of the UDS1 packs and of the cab le.
4. Replace the loc al UDS1 interface circ uit pack, and rep eat the test.
If the UDS1 connects to a line-side terminating device (for example, a PRI
terminal adapter), do the following.
1. Verify that the switch DS1 and the line-side terminating device are
administered using the same signaling mode, framing mode, and line
coding.
2. Investigate the maintenance status of the line-side terminating device.
Refer to the ’Line-Side Terminating Device Operating Manual’ for
information.
3. Contact the vendor of the line-side terminating device to d iagnose the
equipment.
4. Check the physical connection of the UDS1 interface circuit pac k to the
terminating devic e, and check the premise distribut ion system (or the
intra-premise wiring) for physical connection failures.
5. Replace the loc al UDS1 interface circ uit pack and repeat the test.
Table 9-689. TEST #140 Red Alarm Inquiry Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page