DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1136OPS-LINE (DS1 Off Premises Station Line)
9
PASS Trunk translation has been upd ated successfu lly. The current trunk states kept
in the DS1 Interface circuit pack and switch software are consistent. If the trunk
is busied out, the test will not run but will return PASS. To verify that the station
is in-service:
1. Enter the status station command to verify that the station is in-service. If
the station is in-service, no further action is necessary. If the station is
out-of-service, conti nue to step 2.
2. Enter the release station command to put the station back into in-service.
3. Retry the test command.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane bo ard is inserted.
1. Check to ensure that the board translations are correct. Use the list config
command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Table 9-451. TEST #36 Audit and Update Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page