119 FAIL The SNI circuit pack (endpoint 1) cannot communicate with the equipp ed SNI
in slot 19 (list fiber-link can be used to display fiber link endpoints).
1. Perform the ‘‘Fiber Fault Isolation Procedure’’. This sh ould resolve multiple
SNI-PEER err ors.
2. If the SNI being tested has SNI-PEER Error Type 3585, replace the SNI
being tested. Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure for replacing an SNI. To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 3585, replace the SNI
in slot 19.
120 FAIL The SNI circuit pack (endpoint 1) cannot communicate with the equipp ed SNI
in slot 20 (list fiber-link can be used to display fiber link endpoints).
1. Perform the ‘‘Fiber Fault Isolation Procedure’’. This sh ould resolve multiple
SNI-PEER err ors.
2. If the SNI being tested has SNI-PEER Error Type 3841, replace the SNI
being tested. Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure for replacing an SNI. To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 3841, replace the SNI
in slot 20.
133 FAIL No neighbor link is administered, but the SNI (endpoint 1) has an EI neighbor
(list fiber-link can be used to display fiber link endpoints).
1. Administer the SNI on a fiber link to the EI neighbor it is connected to via
the add fiber-link next command. Or remove both fiber endpoints (i.e., this
SNI and its EI neighbor) and remove the fiber endpoints from circuit pack
administration via change circuit-pack.
134 FAIL No neighbor link is administered, but the SNI (endpoint 1) has an SNI neighbor
(list fiber-link can be used to display fiber link endpoints).
1. Administer the SNI on a fiber link to the SNI neighbor it is connected to via
the add fiber-link next command. Or remove both fiber endpoints (i.e., this
SNI a nd its SNI neighbor) and remove th e fiber e ndpoint s from ci rcuit pa c k
administration via change circuit-pack.
Table 9-333. TEST #759 Configuration Audit — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page