DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1037MEM-BD (32MB Memory Circuit Pack)
9
1339 ABORT The test could not run on the standby Memory circuit pack in the standby SPE
carrier because the standby SPE is unavailable.
1. Refer to the section on "STBY-SPE (Standby SPE Maintenance)"
procedures for information on why a standby SPE may be unavailable and
what repair actions should be taken. The status spe screen should
indicate that handshake is down. This may be caused by a variety of
reasons such as the SPE-SELECT switches on the DUPINT circuit packs
being set to the position of the active SPE, a failure of the DUPINT circuit
pack, or loss of power on the standby SPE. The
SPE Selected field
on the
status spe-standby screen will display
spe a
or
spe b
if bot h SPE-SELECT
switches are in the a or b positions, respectively.
2000 ABORT Response to the test request was not received within the allowable time period.
If the system is equipped with the High Reliability or Critical Reliability
Configuration and if the Memory circuit pack is on the standby SPE, this abort
code may indicate that the standby SPE is not responding to the handshake
message. If this is the case, the standby SPE maintenance software may take
up to two minutes to indicate that handshake communication with the standby
SPE is down. The ABORT code will then change to 1339 (handshake
communication down).
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2315 ABORT The test was not run, because this is an extra Memory circuit pack. No testing is
allowed for extra Memory circuit packs.
2334 ABORT The hardware mailbox on the standby Duplication Interface board is not ready
to receive messages.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
FAIL The Burst Read circuit is not functioning properly.
1. If the test fails on more than one Memory circuit pack, replace the
Processor and retry the test.
2. If the test fails only on one Memory circuit pack, replace the affected
Memory circuit pac k.
3. If the test continues to fail only on the same Memory circuit pack, replace
the Processor. To replace the circuit packs, use the procedure described in
Replac ing SPE Ci rcuit Pa cks
in Chapter 5.
PASS The Burst Read portion of the Memory and Processor circuit packs is operating
correctly.
Table 9-410. TEST #908 Memory Burst Read Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page