DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-443CO-TRK (Analog CO Trunk)
9
Port Audit Update Test (#36)
This test will send updates of the CO p ort translation for all ports on the c ircuit
pack which have b een translated. The update is non-d isruptive and guard s
against possible c orruption of translation data c ontained on the circuit p ack. No
response message is expec ted from the circuit p ack once it receives translation
updates. The port translation d ata includes: ground or loop start trunk, tone or
rotary dialing trunk, rotary di aling inter-digit timing , network balance R/RC, and
disconnect timing .
7,
129,
131, or
133
FAIL NOTE:
If the loop around and conference circuit test fails for all ports on a
circuit pac k, a -5 volt power proble m is indicated. To investigate
problems with a power unit, refer to “CARR-POW”. If a red LED on
TN736 or TN752 power unit circuit pack is on, replace the pack. If the
test fails on more than 1 port, check for errors on the TONE-BD or the
TONE-PT. If errors, take appropriate actions. When the tone errors
are cleared, rerun the test. If the test fails again, see FAULT
ISOLATION above.
PASS CO Trunk Looparound and Conference Test is successful. User-reported
troubles on this port should be investigated by using other port tests and by
examining trunk or external wiring.
0NO
BOARD The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-es tablish the linkage
between the internal ID and the port.
Table 9-184. TEST #33 Looparound and Conference
Circuit Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page