DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-444CO-TRK (Analog CO Trunk)

9
Transmission Test (#844-848)
This test is non-destructive.
Table 9-185. TEST #36 Port Audit Update Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1006 ABORT The port has been p laced out of service, p erhaps by craft b usyout.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, wait until the port is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
2100 ABORT System resources required to run this test were not available.
1. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
PASS This test passed. Translation information was successfully updated on the
circuit pack. User-reported troub les on this port should be investigated by
using other port tests and by examining trunk or external wiring. If the trunk is
busied out, the test will not run, but will return PASS. To verify that the trunk is
in-service:
1. Enter status trunk to verify that the trunk is in-service. If the trunk is
in-service, no further ac tion is necessary. If the trunk is out-of-serv ice,
continue to Step 2.
2. Enter release trunk command to put trunk back into in-service.
3. Retry the test command.
0NO
BOARD The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Continued on next page