DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-55ANL-16-L (16-Port Analog Line)
9
Station Present Test (also called Ringing
Application Test) (#48)
This test applies momentary ring ing voltage to the terminal eq uipment and
monitors resulting current flow to d etermine whether terminal equipm ent is
connected to the p ort. This test may cause some terminal equ ipment to ring
briefly during d aily maintenance. If this ringing disturbs the c ustomer or the
terminal equipment, you c an disable it via the Tests field on the change station
form. However, on some software releases, Tests #6, 7, 161, and 35 are disabled.
8 FAIL This does not indicate a hardware problem. There may be an internal
software error. The ringer update failed.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
PASS The software and the port processor have the same status. User-reported
troubles on this port should be investigated by using other port tests, b y
examining station wiring, or by examining the station.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect b oard is
inserted, or an insane board is inserted.
1. Check to ensure the board translations are correct. Use the list config
command and resolve problems.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-e stablish the
linkage between the internal ID and the port. If this is not the case,
check to ensure that there is a valid board inserted.
Table 9-23. Test #36 Station Status and Translation Audits and Updates — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page