DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1768TIE-TRK (Analog Tie Trunk)
9
Tie Trunk Seizure Test (#73) and Tie Trunk Dial Test (#747)
For wink-start, delay-dial and TN2140 (c ont-seize-ack or discont-se ize-ack)
trunks, this test activates the M lead and checks for a respo nse from the far end
within 10 seconds.
For TN497, the test seizes a trunk and outpulses a pause. The port rep orts uplink
the result of the seizure. This test can be disab led via the Test field on the trunk
group administration form.
For TN439, Test #747 is run instead of #73. This test seizes a trunk and outpulses
a pause digit. This test ab orts on ports administered as access endp oints.
Table 9-663. TEST #73,#747 Tie Trunk Seizure Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resourc es required to run this test a re not available. The trunk may be
busy with a valid call. Use the display trunk xx to determine the trunk
group/member num ber of the port. Use th e status trunk command to
determine the service state of the port. If the service state indicates that the port
is in use, then the port is unavailable for certain tests. You must wait until the
port is idle before retesting.
1. If the port status is active, but the port is not in use (no calls), then check
the Error Log for Error Type 1025 (see Error Log table for description of this
error and required actions). The port may be locked up. The far-end PBX
may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
Use the display trunk xx to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the port.
If the service state indicates that the port is in use, then the port is unavailable
for certain tests. You must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT This test is not valid for this trunk translation. Must be a wink-start or delay dial
trunk and must be outgoing or two-way for this test to run. For the TN2140, the
trunk must also be continuous-seize-ack or discontinuous-seize-ack.
1. Check trunk translation. If it is not a wink-start or delay dial trunk, this abort
message should be ig nored.
Continued on next page