DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1770TIE-TRK (Analog Tie Trunk)

9
Tie Trunk EPF Test (#74)

The first part of this test checks for p roper activation and d eactivation of the

port’s E lead. The second p art checks the M lead el ectronic power feed c urrent

flow.

Table 9-664. TEST #74 Tie Trunk EPF Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run the test. This could be
due to a failure to seize the p ort.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resourc es required to run this test are not av ailable. The trunk may be
busy with a valid call. Use the display trunk xx to determine trunk
group/member num ber of the port. Use the s tatus trunk command to
determine the servic e state of the port. If the servic e state indicates that the port
is in use, then the port is unavailab le for certain tests. You must wait until the por t
is idle before retesting.
1. If the port status is active, but the port is not in use (no calls), then check the
Error Log for Error Type 1025 (see Error Log table for description of this
error and required actions). The port may be locked up. The far-end PBX
may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
Use the display trunk xx to determine the trunk group/member number of the
port. Use the status trunk command to determine the servic e state of the port.
If the service state indicates that the port is in use, then the port is unavailable
for certain tests. You must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT This test is not valid for this trunk translation. Must be a type-1 standard trunk for
this test to run.
1. Check trunk c onfiguration. If it is not a typ e-1 standard trunk, this a b ort
message should be ig nored.
1014 ABORT The test was aborted because the circuit p ack has not been inserted into the
system.
1. Use the list configuration board command to make sure the circuit pack is
inserted in the carrier.
2. If the board is not inserted, make sure the circuit pack is inserted in the
carrier and fully seated.
Continued on next page