DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-352test mass-storage
8
The following display shows a typical result when test maintenance 2 is entered.
test mass-storage
test mass-storage [C] [short | long] [repeat | clear] [schedule]
This command performs tests on each of the 3 componen ts of the Mass Storage
System (MSS): the host adapter circuit on the MSSNET circuit pack, the tap e
circuit pack and the disk circu it pack. Each of the 3 objec ts is tested using the
same sequence used w hen individual comp onents are tested separately.
This command aborts if any other mass -storage operation has already begun.
Failure of the host-adapter test may result in the disab ling of periodic and
scheduled testing of the failed host-adap ter and the related tape an d disk.
Failure of a tape or disk test may result in the disabling of periodic and scheduled
testing of the component.
The cabinet is always 1 and need not be entered. Carrier a or b must be
specified only for systems with duplicated SPEs.
test maintenance
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A SYSAM 911 PASS
01A SYSAM 913 PASS
01A SYSAM 915 PASS
Command Successfully Completed
test maintenance 2
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
02A MAINT 106 PASS
02A MAINT 229 PASS
02A MAINT 303 PASS
02A MAINT 854 PASS
02A MAINT 337 PASS
Command Successfully Completed