DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-76display atm pnc
8
For the following example, the ENTER key was pressed immediately after entering
the display alarms print command.
Feature Interactions
If the alarm origination is disab led by “chang e system-parameters maintenance,”
the Ack? field display s blanks no matter what the true acknowled ge state is for
the alarm.
If “second-as-b ackup” is ad ministered in the Alarm Origination to OSS
Numbers field, the column under the “ 2” heading will b e blank for the alarms that
the switch has not attempted to send to the second OSS telephone num ber. For
the alarms that the switch has attempte d to send to the second OSS telephone
number, the column will be “ y,” “n,” or “c ,” depend ing on the acknowled gment
status of the alarm. After calling the fi rst OSS telephone number becomes
successful, for the alarms that the s witch has attempted to send to OSSN2, the
column will be consistent with the column under the “1 ” heading.
display atm pnc
This command displays specific atm pnc data.
display alarms
ALARM REPORT
Port Maintenance On Alt Alarm Svc Ack? Date Date
Name Brd? Name Type State 1 2 Alarmed Resolved
02A TONE-BD y MAJOR y n 05/22/20:34 00/00/00:00
01C07 ANL-BD y MINOR n n 05/22/20:26 00/00/00:00
01C0702 ANL-LINE n 311 WARNING IN 05/22/20:26 00/00/00:00
01C0701 ANL-LINE n 1051 WARNING IN 05/22/20:26 00/00/00:00
01C0703 ANL-LINE n 1053 WARNING IN 05/22/20:26 00/00/00:00
01C1505 CO-TRK n 78/01 WARNING OUT 05/22/20:26 00/00/00:00
01C1505 CO-TRK n 78/01 WARNING OUT 05/22/20:26 00/00/00:00
02A0201 TONE-PT n WARNING 05/22/20:34 00/00/00:00
02A TDM-CLK n WARNING 05/23/13:43 00/00/00:00
PN 02B TDM-BUS n WARNING 05/23/14:53 00/00/00:00
Command successfully completed