DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-39ADX16A-PT (AUDIX Analog Line/Control Link)
9
1003 ABORT The system could not alloc ate a tone receiver for the test. The syste m may be
oversized for the number of tone detectors present or some tone detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals for a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the port is in use, wait until the port is idle before
testing.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
1018 ABORT Test disabled by administration. To enable the test for the particular analog
station, enter the change station <extension> command and change the
‘‘Test?’’ field on the Station Form from ‘‘n’’ to ‘‘y.’’
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL The reflective Looparound Test failed. This causes noisy or unreliable
connections or other users calling this port may hear an echo.
1. Replace the circuit pack.
PASS The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investig ated by
using other port tests, by examining station wiring, or by examining the
station.
Table 9-15. TEST #161 Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page