DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-45ANL-16-L (16-Port Analog Line)

9
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors and can only be resolved over time. Aux Data 40960 indicates that too many simultaneous incoming ring ing attempts were made on this board . Only 4 ports on a board may ring simultaneously. A 5th incoming call c auses an inline error from the board.Table 9-19. 16-Port Analog Line Error Log Entries
Error
Type Aux
Data Associated
Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port UUCSSpp sh r 1
1(a) 40960
40975
40977
none
15(b) Any Audits and
Updates Test
(#36)
18 0 busy-out
station
extension
WRN ON release station
extension
130(c) None WRN ON test port UUCSSpp sh
257(d) 40973 none
513(e) Station
Present Test
(#48)
WRN OFF test port UUCSSpp sh r 2
769 Battery Feed
Test (#35) MIN/ WRN2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON test port UUCSSpp sh r 2
1025 Looparound
Test (#161) MIN/ WRN2ON test port UUCSSpp l r 2
1281 Conference
Test (#7) MIN/ WRN2ON test port UUCSSpp l r 2
1537 NPE
Crosstalk Test
(#6)
MIN/ WRN2ON test port UUCSSpp l r 2