DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1278PKT-INT (Packet Interface Circuit Pack)
9
1362 ABORT The Reset test is not allowed to run because the Packet Interface circuit pack
is in service. Resetting a Packet Interface circuit pack that is in-service on an
activ e SPE is not allowe d sinc e this is a de struc tive te st (exi sting phone calls
involving telephones connected to Expansion Port Networks would be
disconnected).
1. Use the status packet-interface command to determine the service state
of the Packet Interface circuit pack. If the state is "out-of-service", try the
Reset command again.
2000 ABORT Response to the test request was not received within the allowable time
period. If the system is equipped with the High Reliability or Critical Reliability
Configuration and if the Packet Interface circuit pack is on the standby SPE,
this abort code may indicate that the standby SPE is not responding to the
handshake message. If this is the case, the standby SPE maintenance
software may take up to two minutes to indicate that handshake
communication with the standby SPE is down. The ABORT code will then
change to 1339 (standby SPE unavailable).
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2500 ABORT Internal system error
1. Retry the command.
Table 9-503. TEST #889 Reset Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page