Maintenance Object Repair Procedures
9-479DID-DS1 (Direct Inward Dial Trunk)
9
1000 ABORT System resources required for this test were not available. The port may be
busy with a valid call.
1. Use display port UUCSSpp to determine the trunk group/member
number of the port. Use status trunk to determine the service state of the
port. If the port is in use, wait until the port is idle before testing.
2. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots out of service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors an d is not handling heavy traffic and
the port status is idle, retry the command at 1-minute intervals a maximum
of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some of the tone
detectors may be out of service. Use list measurements tone-receiver to
display information ab out the tone receivers.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a user for a valid call.
1. Use display port UUCSSpp to determine the trunk group/member
number of the port. Issue the status trunk command to determine the
service state of the port. If the port is in use, wait until the port is idle before
testing.
2. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
1018 ABORT The test was disabled via translation. Determine why the test has been
disabled before you enable it.
1. Verify that the Maintenance Test field on the Trunk Administration
screen is set to n. To enable the test, change the trunk administration and
enter y for this field.
2. Repeat the test.
Table 9-197. TEST #7 Conference Circuit Test — Continued
Error
Code Test
Result Description/ Recommendation