DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1663TAPE
9
5224 File 12 (announcement file) corrupt.
5225 File 13 (alternate announcement file) corrupt.
5226 File 14 (maintenance scratch file) corrupt.
5227 File 15 (small config core dump) corrupt.
5228 File 16 (large boot image) corrupt.
5229 File 17 (alternate boot imag e) corrupt.
5230 File 18 (large core dump on disk) corrupt.
5231 File 19 (large core dump on tape) corrupt.
5300 Command timed out.
5301 Driver ran out of resources.
5302 Device or host adapter is not ready.
5303 State information is invalid.
5304 Firmware returned unexpected tag.
5305 MSSNET board is not inserted.
5400 Initialization error.
5401 Kernel call failed .
5402 Timer call failed.
5403 DUPINT call failed.
5404 DRIP call failed.
5405 Critical path d estroyed.
5406 Internal error.
5504 Block reassigned on tape as a result of a medium error
5505 While running status test, configuration test failed.
5506 While running status test, LED test failed.
5507 Status test found host adapter in "held reset" state.
5508 Unable to obtain path to PAM.
5509 Translations were not locked.
5510 +5V not present
5511 +12V not present
5512 Exceeded 90% of manufacturer’s recommended tape access limit.
Table 9-624. MSS Error Actions — Continued
Code Description
Continued on next page