DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-562DISK (MSS Disk Circuit Pack)
9
Disk Reset Test (#894)
The Disk Reset Test is executed when the reset disk command is entered at the
terminal. The test results for Test 894 are the same as those for Test 809. The only
difference between Test 809, which is run as part o f the test sequence for the
test disk command, and Test 894 which is run in resp onse to the reset disk
command is that all d isk alarms are resolved when Test 894 passes while only
some disk alarms may be resolved when Test 809 passes.
Refer to the results for Test #809 for the appropriate repair proced ures.
Any
Other1FAIL The disk configuration information shows the disk is missing or the disk LED test
failed.
1. Retry the command a maximum of 5 times.
2. If the command continues to fail, replace the Disk Drive circuit p ack, issue
the reset disk command and perform the restore disk com mand. This will
take up to 1 hour for a complete restore.
3. If the test continues to fail, replace the MSSNET circuit pack.
PASS The Disk status test passed successfully. Look at the results of other tests to
see if it is operating correctly.
1. See the MSS Error Actions Table at the end of the TAPE section.
Table 9-230. TEST #815 Disk Status Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page