DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1480SNI-BD (SNI Circuit Pack)
9
2100 ABORT Could not allocate the necessary syst em resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2300 ABORT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2301 ABORT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2306 ABORT The SNI circuit pack is not responding to test requests sent by software.
1. Run the test led switch-node for the switch node that the SNI resides in to
verify whether the LEDs on the board light.
2. If the LEDs on the other boards in the carrier light, but the LEDs on this
board do not light, run test 760 via test board UUCSS l for the active SNC
in this carrier. Wait 5 minutes and then try step 1 one more time. If the
LEDs on this board still do not light, replace this board. Replacing an SNI
may be service interrupting. Refer to the SNI-BD section for the procedure
for replacing an SNI.
3. If none of the LEDs light for the boards in the same carrier as this board, fix
any problems associated with the connectivity of this carrier to the SPE.
Check list fiber-link to determine the fiber connections to this carrier.
Check the LEDs on all SNIs and EIs and fix any fiber problems. Enter
display errors and follow the associated repair proced ures for any
EXP-INTF error entries associated with the PPN. Also, follow the
associated repair procedures for any SYNC, SNI-BD, SNC-BD, FIBER-LK,
or SNI-PEER e rror en tries .
4. Follow the procedure described above, SNI Manual Loopback to
determine whether the circuit pack or the fiber connection is faulty.
Table 9-565. TEST #777 Failure Audit — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page